Modbus_LoRaWAN:NB-IoT
Modbus_LoRaWAN:NB-IoT
Modbus_LoRaWAN:NB-IoT
Modbus_LoRaWAN:NB-IoT
Modbus_LoRaWAN:NB-IoT
Dispositif de commutation ROSSMA® IIOT-AMS Modbus
Dispositif de commutation pour controleurs industriels via les interfaces RS-485, RS-232, RS-422 avec MODBUS et transmission de donnees via les reseaux sans fil LPWAN LoRaWAN et NB-IoT avec prise en charge du controle a distance. Avec possibilite de configuration et de liaison a distance.
Aperçu
Fonctionnalités
- Fonctionnement simultane de jusqu’a 64 appareils RS-485/RS-422 ou jusqu’a 16 appareils RS-232.
- Controle d’appareils d’automatisation externes.
- Alimentation 220V integree.
- Memoire non volatile integree.
- Possibilite de configuration.
- Transmission de donnees par paquets.
Outdoor IP65
Alimentation 220V, 5-30V
Documentation
Manuel d'utilisation Ouvrir dans Wiki ↗
ROSSMA IIOT-AMS MODBUS meter-switch is designed for autonomous polling of industrial instruments/controllers via RS-485 interfaces, with subsequent wireless data transmission. Additionally equipped with three independent inputs for pulse counting or for monitoring state changes on each input (closed/open) and an additional output for powering external devices with 5 V. Features remote configuration and binding capabilities.

Fig. ROSSMA IIOT-AMS MODBUS meter-switch appearance
Technical Specifications
Inputs / Connection Interfaces:
- 1 RS-485 serial interface | for MODBUS modifications
- 3 multifunctional discrete inputs | for MODBUS modifications
- Built-in temperature sensor
- Battery voltage measurement
Electrical Characteristics:
- Supply voltage (external power from AC mains MODBUS): 230 V
- Supply voltage (autonomous power): 3.3 V to 3.6 V
- Power consumption (autonomous): 0.99 W
- Power consumption (external 230 V power): 62.7 W
- Current consumption (autonomous): 0.3 A
- Current consumption (external power): 0.3 A
Operating Characteristics:
- Operating temperature range: -55…+80°C
- Protection degree (general industrial version): IP65 and IP66
- Explosion protection marking: 1Ex e IIC T4 Gb X
- Where X in marking indicates special conditions: device operating temperature range -55°C..+80°C
LoRaWAN Network Characteristics:
- Device class: LoRaWAN A or B
- Frequency plan: RU868, EU868, IN865, AS923, AU915, KR920, US915, KZ865
- Activation method: ABP or OTAA (configurable), default ABP
- Communication interval: configurable via LoRaWAN network
- Built-in antenna, sensitivity: -138 dBm
- Radio communication range: up to 5 km in dense urban areas; up to 15 km outside populated areas
- Transmitter power: default 25 mW, maximum 100 mW
NB-IoT Network Characteristics:
- Frequency plan: B1/2/3/5/8/12/13/17/18/19/20/25/26/28/66/70
- Communication interval: configurable
- Built-in antenna
- Sensitivity: -138 dBm
- Radio communication range: up to 5 km in dense urban areas; up to 15 km outside populated areas
- Transmitter power: default 25 mW, maximum 100 mW
Housing Options:
- General industrial version: 115×90×50
- Explosion-proof version: 260×160×90, 220×120×90, 80×75×55
- Cable gland types: specified in agreement with customer
- Mounting: DIN rail adapter or mounting loops
Capabilities
- Simultaneous operation of up to 8 devices via RS-485
- External automation device control
- Built-in 220 V power supply
- Built-in non-volatile memory
- Configuration capability
- Batch data transmission
Application Areas
- Data collection and remote control of technological equipment
- Applicable for oil production industry for process control systems
- Control stations for ESP / EODN / SGPS / HGPS / SNU / UNU / UDS (OU)
- Gas separator installations, pumping stations
- Electrochemical protection stations
- Reagent supply/dosing units
- Data collection from instruments with RS-485 interface
LED Indication
ROSSMA IIOT-AMS MODBUS meter-switch has the following indicators:
- ACT - data exchange with sensor or controller via MODBUS protocol
- Lora - transmitting/receiving data via LoRaWAN network
- Err - indicator signals MODBUS protocol exchange error
- PWR - power
- NET - NB-IoT network connection
- Success - successful NB-IoT transmission
ROSSMA IIOT-AMS MODBUS meter-switch has a RESET button for device reset.
Modbus Device Configurator go to
Equipment is registered in the register of the Ministry of Industry and Trade of the Russian Federation as equipment manufactured on the territory of the Russian Federation (Conclusion 48859/11 dated June 11, 2021).
Firmware
Main Microcontroller (MainMCU)
Version: 0.3.5d (01.06.2025) — ⬇️ Download
What's new in v0.3.5d:
- Improved LoRaWAN module for large packet transmission
v0.3.5c (26.05.2025) — Fixed version formatting
v0.3.5b (20.05.2025):
- Improved secondary MCU message handling algorithm
- Improved im880 interaction module
- Improved message formation module
v0.3.5a (20.05.2025):
- Support for new secondary MCU type
- New algorithm for secondary MCU message handling
- New data transfer algorithm between secondary and main MCU
📋 Version History
v0.3.4 (29.03.2025)
- Internal archive support and time setting
- Time setting command 0xCB (Unix Timestamp)
- Time request commands 0xCA (main MCU) and 0xC5 (secondary MCU)
v0.3.3 (14.03.2025)
- Secondary MCU time reading command
- Restart reason command
- Monitoring period read/write commands
- Changed EEPROM structure
v0.3.2 (27.02.2025) — Software reset of LoRaWAN module (im880)
v0.3.1 (09.02.2025)
- Support for secondary MCU with display control logic
- Display control commands (0xD1 - 0xD6)
LoRaWAN Communication Module
Version: 0.4.4c (01.06.2025) — ⬇️ Download
What's new in v0.4.4c:
- Improved LoRaWAN module for large packet transmission
v0.4.4b (26.05.2025):
- Improved secondary MCU message handling algorithm
- Improved im880 interaction module
- Improved message formation module
v0.4.4a (20.05.2025) — New data transfer algorithm between primary MCU and communication module
📋 Version History
v0.4.3b (28.04.2025) — Fixed command processing, changed multi-packet settings storage
v0.4.3a (24.04.2025)
- Multi-packet transmission
- ADR mode switching
- Default DataRate change
- Auto-adjustment of packet length based on DataRate
v0.4.2c (24.02.2025)
- Additional restart reason code
- Software Watchdog improvements
- Debug mode for interrupts
v0.4.2b (28.01.2025)
- Redesigned port selection algorithm
- New EEPROM structure with integrity check
- Software WDG with 10-minute timeout
- Module restart command (0xCE on port 15)
Secondary Microcontroller (SecMCU)
Version: 0.11.1d (09.04.2025) — ⬇️ Download
What's new in v0.11.1d:
- Fixed archive data search that in some cases caused MCU freeze
v0.11.1c (07.04.2025) — Fixed monitoring result processing when registers are missing
v0.11.1b (06.04.2025) — Fixed sending monitoring messages with errors
v0.11.1a (03.04.2025):
- Additional timeout after monitoring trigger
- Improved error message formation algorithm
- Timeout (PERIOD × 60 sec) after 3 consecutive monitoring errors
📋 Version History
v0.11 (29.03.2025)
- Internal archive support (36 records, 12 flash pages)
- Real-time clock support
- New internal commands for archive output
v0.10.7 (14.03.2025)
- Restart reason support
- Monitoring time change
- Monitoring optimization
v0.10.6 (27.02.2025) — Added profiles 0x2D, 0x48, 0x49, 0x4A, 0x4B, 0xE1, 0xE2
How to update: Use ST-LINK programmer for flashing via SWD interface.
Additional Information
- Device Installation — installation instructions
- Battery Replacement — battery replacement
- Protocols and Commands — control commands and data formats
- ROSSMA Configurator — device configuration
- Troubleshooting — diagnostics and problem solving
Related Pages
Software:
- ROSSMA Configurator — Modbus profile settings, transmission intervals
- ROSSMA NETS Server — telemetry viewing, device management
- Data Decoder — Modbus payload analysis
Technical Documentation:
- Exchange Protocols — MODBUS device packet format
- LoRaWAN Technology — RU864 frequency plan, device classes
- Quick Start — first network connection
Other Devices:
- ANALOG Single Channel — for 4-20 mA sensors
- PULSE — for pulse sensors
- Device Catalog — all ROSSMA IIoT-AMS models
Fonctionne avec les capteurs suivants :
APPLICATIONS :
- Collecte de donnees et controle a distance des equipements de processus.
- Applicable pour l’industrie de production petroliere pour les SCADA :
- Stations de controle PES / PEO / SRPU / HRPU / PU / RDU / UDS (CU) ;
- AGZU, Stations de pompage ;
- Stations de protection cathodique ;
- Unites de dosage/injection de reactifs.
- Collecte de donnees des instruments avec interface RS-485.
L’equipement est inscrit au registre du Ministere de l’Industrie et du Commerce de la Federation de Russie en tant qu’equipement fabrique en Federation de Russie (Certificat 48859/11 du 11.06.2021).
Logiciel
Application configurateur pour la configuration à distance des dispositifs de commutation ROSSMA® IIOT-AMS