Wireless Modbus-LoRaWAN Gateway ROSSMA® IIOT-AMS Modbus

Wireless industrial Modbus RS-485 to LoRaWAN/NB-IoT gateway with remote control. Connect controllers and instruments via RS-485, RS-232, RS-422.

Recommended Popular
LoRaWAN LTE NB-IoT
Protocol Modbus RTU (RS-485)
Number of inputs RS-485 + 3 discrete
Explosion protection 1Ex e IIC T4 Gb X, IP65/IP66
Operating temperature -55...+80 °C
Price on request

Overview

Features

  • Simultaneous operation of up to 64 RS-485/RS-422 devices or up to 16 RS-232 devices.
  • External automation device control.
  • Built-in 220V power supply.
  • Built-in non-volatile memory.
  • Configuration capability.
  • Packet data transmission.
Housing:
Outdoor IP65
Power:
Power supply 220V, 5-30V

Specifications

Measurement
Protocol
Modbus RTU (RS-485)
Number of inputs
1 RS-485 + 3 discrete inputs
Communications
LoRaWAN class
A or B
Activation
ABP / OTAA (configurable)
TX power
up to 100 mW (configurable), default 25 mW
Sensitivity
-138 dBm
Communication range
up to 5 km (urban) / 15 km (rural)
Frequency plan
RU868, EU868, IN865, AS923, AU915, KR920, US915, KZ865
Housing & Protection
IP rating
IP65 / IP66
Explosion protection
1Ex e IIC T4 Gb X
Mounting
DIN rail adapter or mounting ears
Power
Power type
Mains 230V AC / autonomous 3.3-3.6V
Operating Conditions
Operating temperature
-55...+80 °C

Documentation

User Manual Open in Wiki ↗

ROSSMA IIOT-AMS MODBUS meter-switch is designed for autonomous polling of industrial instruments/controllers via RS-485 interfaces, with subsequent wireless data transmission. Additionally equipped with three independent inputs for pulse counting or for monitoring state changes on each input (closed/open) and an additional output for powering external devices with 5 V. Features remote configuration and binding capabilities.

ROSSMA IIOT-AMS MODBUS

Fig. ROSSMA IIOT-AMS MODBUS meter-switch appearance

Technical Specifications


Inputs / Connection Interfaces:

  • 1 RS-485 serial interface | for MODBUS modifications
  • 3 multifunctional discrete inputs | for MODBUS modifications
  • Built-in temperature sensor
  • Battery voltage measurement

Electrical Characteristics:

  • Supply voltage (external power from AC mains MODBUS): 230 V
  • Supply voltage (autonomous power): 3.3 V to 3.6 V
  • Power consumption (autonomous): 0.99 W
  • Power consumption (external 230 V power): 62.7 W
  • Current consumption (autonomous): 0.3 A
  • Current consumption (external power): 0.3 A

Operating Characteristics:

  • Operating temperature range: -55…+80°C
  • Protection degree (general industrial version): IP65 and IP66
  • Explosion protection marking: 1Ex e IIC T4 Gb X / 1Ex db IIC T5 Gb X
    • Where X in marking indicates special conditions: device operating temperature range -55°C..+80°C

LoRaWAN Network Characteristics:

  • Device class: LoRaWAN A or B
  • Frequency plan: RU868, EU868, IN865, AS923, AU915, KR920, US915, KZ865
  • Activation method: ABP or OTAA (configurable), default ABP
  • Communication interval: configurable via LoRaWAN network
  • Built-in antenna, sensitivity: -138 dBm
  • Radio communication range: up to 5 km in dense urban areas; up to 15 km outside populated areas
  • Transmitter power: default 25 mW, maximum 100 mW

NB-IoT Network Characteristics:

  • Frequency plan: B1/2/3/5/8/12/13/17/18/19/20/25/26/28/66/70
  • Communication interval: configurable
  • Built-in antenna
  • Sensitivity: -138 dBm
  • Radio communication range: up to 5 km in dense urban areas; up to 15 km outside populated areas
  • Transmitter power: default 25 mW, maximum 100 mW

Housing Options:

  • General industrial version: 115×90×50
  • Explosion-proof version: 260×160×90, 80×75×55
  • Cable gland types: specified in agreement with customer
  • Mounting: DIN rail adapter or mounting loops
ROSSMA IIOT-AMS MODBUS

Capabilities


  • Simultaneous operation of up to 8 devices via RS-485
  • External automation device control
  • Built-in 220 V power supply
  • Built-in non-volatile memory
  • Configuration capability
  • Batch data transmission

Application Areas


  • Data collection and remote control of technological equipment
  • Applicable for oil production industry for process control systems
  • Control stations for ESP / EODN / SGPS / HGPS / SNU / UNU / UDS (OU)
  • Gas separator installations, pumping stations
  • Electrochemical protection stations
  • Reagent supply/dosing units
  • Data collection from instruments with RS-485 interface

LED Indication


ROSSMA IIOT-AMS MODBUS meter-switch has the following indicators:

  • ACT - data exchange with sensor or controller via MODBUS protocol
  • Lora - transmitting/receiving data via LoRaWAN network
  • Err - indicator signals MODBUS protocol exchange error
  • PWR - power
  • NET - NB-IoT network connection
  • Success - successful NB-IoT transmission

ROSSMA IIOT-AMS MODBUS meter-switch has a RESET button for device reset.

Modbus Device Configurator go to

Equipment is registered in the register of the Ministry of Industry and Trade of the Russian Federation as equipment manufactured on the territory of the Russian Federation (Conclusion 48859/11 dated June 11, 2021).


Firmware

Main Microcontroller (MainMCU)

Version: 0.3.5d (01.06.2025) — ⬇️ Download

What's new in v0.3.5d:

  • Improved LoRaWAN module for large packet transmission

v0.3.5c (26.05.2025) — Fixed version formatting

v0.3.5b (20.05.2025):

  • Improved secondary MCU message handling algorithm
  • Improved im880 interaction module
  • Improved message formation module

v0.3.5a (20.05.2025):

  • Support for new secondary MCU type
  • New algorithm for secondary MCU message handling
  • New data transfer algorithm between secondary and main MCU
📋 Version History

v0.3.4 (29.03.2025)

  • Internal archive support and time setting
  • Time setting command 0xCB (Unix Timestamp)
  • Time request commands 0xCA (main MCU) and 0xC5 (secondary MCU)

v0.3.3 (14.03.2025)

  • Secondary MCU time reading command
  • Restart reason command
  • Monitoring period read/write commands
  • Changed EEPROM structure

v0.3.2 (27.02.2025) — Software reset of LoRaWAN module (im880)

v0.3.1 (09.02.2025)

  • Support for secondary MCU with display control logic
  • Display control commands (0xD1 - 0xD6)

LoRaWAN Communication Module

Version: 0.4.4c (01.06.2025) — ⬇️ Download

What's new in v0.4.4c:

  • Improved LoRaWAN module for large packet transmission

v0.4.4b (26.05.2025):

  • Improved secondary MCU message handling algorithm
  • Improved im880 interaction module
  • Improved message formation module

v0.4.4a (20.05.2025) — New data transfer algorithm between primary MCU and communication module

📋 Version History

v0.4.3b (28.04.2025) — Fixed command processing, changed multi-packet settings storage

v0.4.3a (24.04.2025)

  • Multi-packet transmission
  • ADR mode switching
  • Default DataRate change
  • Auto-adjustment of packet length based on DataRate

v0.4.2c (24.02.2025)

  • Additional restart reason code
  • Software Watchdog improvements
  • Debug mode for interrupts

v0.4.2b (28.01.2025)

  • Redesigned port selection algorithm
  • New EEPROM structure with integrity check
  • Software WDG with 10-minute timeout
  • Module restart command (0xCE on port 15)

Secondary Microcontroller (SecMCU)

Version: 0.11.1d (09.04.2025) — ⬇️ Download

What's new in v0.11.1d:

  • Fixed archive data search that in some cases caused MCU freeze

v0.11.1c (07.04.2025) — Fixed monitoring result processing when registers are missing

v0.11.1b (06.04.2025) — Fixed sending monitoring messages with errors

v0.11.1a (03.04.2025):

  • Additional timeout after monitoring trigger
  • Improved error message formation algorithm
  • Timeout (PERIOD × 60 sec) after 3 consecutive monitoring errors
📋 Version History

v0.11 (29.03.2025)

  • Internal archive support (36 records, 12 flash pages)
  • Real-time clock support
  • New internal commands for archive output

v0.10.7 (14.03.2025)

  • Restart reason support
  • Monitoring time change
  • Monitoring optimization

v0.10.6 (27.02.2025) — Added profiles 0x2D, 0x48, 0x49, 0x4A, 0x4B, 0xE1, 0xE2

How to update: Use ST-LINK programmer for flashing via SWD interface.


Additional Information


Software:

Technical Documentation:

Other Devices:

Works with the following sensors:

APPLICATIONS:

  • Data collection and remote control of process equipment.
  • Applicable for the oil production industry for APCS:
    • ESP / EOP / SRPU / HRPU / PU / RDU / UDS (CU) control stations;
    • AGZU, Pump stations;
    • Cathodic protection stations;
    • Reagent dosing/injection units.
  • Data collection from instrumentation with RS-485 interface.

The equipment is registered in the Registry of the Ministry of Industry and Trade of the Russian Federation as equipment manufactured in the Russian Federation (Certificate 48859/11 dated 11.06.2021).

Software

Configurator application for remote configuration of ROSSMA® IIOT-AMS switching devices

Frequently Asked Questions

What industrial instruments can be connected to the wireless Modbus gateway?
Any RS-485 Modbus RTU devices: controllers, VFDs, flow meters, gas analyzers, heat calculators, energy meters. Plus 3 additional discrete inputs.
Is remote control available?
Yes. ROSSMA® IIOT-AMS Modbus supports LoRaWAN Class C — the device is always listening and can execute remote control commands. This enables remote equipment management via SCADA.
Is external power required?
The gateway runs on 230V AC mains or autonomously on a 3.3–3.6V battery. Mains power enables Class C mode (continuous listening). Battery power uses Class A (energy-saving).
What is the data transmission range?
Up to 5 km urban / 15 km open terrain via LoRaWAN. Supports 8 frequency plans for different countries. Transmitter power adjustable up to 100 mW.
What interfaces does the gateway support?
RS-485 (primary), RS-232, and RS-422 for various industrial instruments. IP65/IP66 protection. Operating temperature −55…+85 °C.
How does the industrial Modbus differ from Modbus Utility for utilities?
Industrial Modbus is designed for harsh conditions and equipment control (Class C). Modbus Utility is optimized for utility meter connections with emphasis on energy efficiency.
Interested Wireless Modbus-LoRaWAN Gateway ROSSMA® IIOT-AMS Modbus?

Office

9D Chkalova St., office 320, 322 Perm, Perm Krai Russia, 614064

Manufacturing

9 Chkalova St., building 3 Perm, Perm Krai Russia, 614064

Success

Your email has been added to the mailing list

Subscribe to news

Weekly industry news digest